Cigarette Smoke: Size Distribution and Effects on Filters

Cigarette smoke is an important aerosol in the air filtration industry and research. It is an unwanted aerosol and therefore there are many applications for air filtration (ex. cigarette filters, residential and commercial ventilation filters, home air cleaners).

Cigarette smoke is especially important to air filter performance for several reasons. First, the size of cigarette smoke particles (see table below) are near the most penetrating size of air filters (100-300 nm). As a result, they are relatively difficult to capture. Secondly, the efficiency of electret filter is severely degraded by the semi-volatile cigarette particles. It is believed that they form a film on the fiber surface and effectively shield or remove the charges. If this occurs, the electrostatic efficiency of the filter suffers. The remaining mechanical efficiency is usually poor because electret is a depth filter and the fiber size is relatively large. Furthermore, a cigarette can produce a large amount of aerosol quickly. Imagine a room with several cigarette smokers! Whereas large particle (>5 micrometer diameter) tends to settle down by gravity quickly, cigarette smokes are relatively stable and their lifetimes can be on the order of days or weeks. Therefore, cigarette smoke can be viewed as a stringent test for air filters.

Table 1 lists the results of particle size measurements done by previous researchers. As seen below, the count median particle size is between 0.1 to 0.3 μm, near the most penetration particle size of high efficiency particulate arrestor (HEPA) filters. For depth filtration media like microfiberglass, the loading of smoke particles would not be detrimental because the oil droplets can wet the fibers and spread out. For microporous membrane, the loading of smoke particles can have a detrimental effect on the pressure drop. Due to surface filtration, the oil droplets are collected near the surface. As the oil accumulates on the surface, it chokes off the airflow. It is therefore not recommended to use microporous membrane in environments with cigarette smokers.

Table 1. Survey of cigarette smoke particle size measurements done by researchers.

Reference

Method

Smoke Source

Arithmetic Mean Dia. μm)

Count Median Dia. (μm)

Geo. St. Dev.

Mass Median Dia.(μm)

Sinclair (1950)

Light scattering

 

 

0.3

 

 

Okada & Matsunuma (1974)

 

Light scattering

 

mainstream

 

0.163-0.179

 

 

sidestream

 

0.095-0.118

 

 

Ingebrethsen (1986)

Light scattering

 

 

 

 

0.25-0.35

Dalla Valle et al. (1954)

Electrostatic separation

 

 

0.1-0.25

 

 

Anderson et al. (1989)

Electrical aerosol analyzer

 

 

 

 

0.38

Wells and Gerke (1919)

Oscillation in electric field

 

0.27

 

 

 

Keith and Derrick (1960)

Conifuge

 

0.2 to 0.25 (size range from 0.1-1.0)

 

 

 

Porstenorfer and Schraub (1972)

Radon attachment and centrifugal deposition

mainstream

0.22

 

 

 

Carter and Hasegawa (1975)

Electron microscopy

 

0.45

 

 

 

Holmberg (1979)

SEM

 

0.29-0.40

 

 

 

Keith (1982)

SEM

 

0.20

 

 

 

Phalen et al. (1976)

 

 

Cascade impactor

 

 

 

 

0.71-0.73

Centrifugal spiral aerosol separator
Electron microscopy

 

 

0.57

 

 

 

 

0.72-0.79

 

Hinds (1978)

Aerosol centrifuge & cascade impactor

 

 

 

 

0.52 (tp 0.38 as dilution increased)

Chang et al. (1985)

Cascade impactor

mainstream

 

bimodal: 0.25 and 5

 

 

Chung & Dunn-Rankin (1996)

 

 

 

Light scattering

 

 

 

mainstream w/o filter (1R3)

0.15

0.14

2.1

0.71

mainstream w/ filter (1R3f) 0.18

0.17

2.0

0.66

fresh sidestream smoke 0.27

0.27

1.6

0.50

captured sidestream smoke 0.26

0.25

1.7

0.52

Reference

I. Ching and D. Dunn-Rankin (1996) Light Scattering Measurements of Cigarette Smoke. Aerosol Sci. Tech. 24:85-101

Author

Dr. Wilson Poon has 18 years of experience in particle technology and filtration research. He received his Ph.D. in 1997 from the Department of Mechanical Engineering, University of Minnesota. His current position is senior technologist at W.L. Gore & Associates, Inc. specializing in air filtration research and filter media development.

To learn more about filtration and to network with experts in the field attend an AFS Conference or Short Course.

 

If you want to receive a short filtration lesson every month, sign up for the AFS e-newsletter.

Join the AFS list and receive the monthly newsletter.
Enter Email:

© 2009 American Filtration & Separations Society All rights reserved


 
 

Search the AFS Site


powered by FreeFind

Site map


American Filtration & Separations Society
7608 Emerson Avenue South
Richfield, MN 55423
Phone (612) 861-1277
Fax (612) 861-7959
©2005-10 All rights reserved